A cooling fan

2015-04-17  Hits:199

 

Cooling fans, English name: Cooling fans, fan sizes from 8 mm to 280 mm, the voltage is 5 v, 12 v, 24 v, 48 v, 110 v, 220 v, 380 v, form a square, circular, olive shape, etc.

The principle of

The working principle of the cooling fan is implemented according to the energy conversion, namely: the electrical energy to electromagnetic energy, mechanical energy to kinetic energy. The circuit principle generally divided into a variety of forms, the circuit is different, the performance of the fan will have difference.

classification

Axial flow fan

Axial flow fan blades air moving in the same as the axis direction. Axial flow fan impeller and propeller are similar, it at work, the vast majority of the flow of air flow parallel to the axis, in other words, along the axis direction. Axial flow fan when the inlet air flow is 0 static pressure free air, the minimum power consumption, as the jet backpressure rises when running power consumption will increase. Axial flow fan is usually served on electrical equipment cabinets, sometimes integration on the motor, because of the axial flow fan is compact structure, can save a lot of space, easy installation at the same time, so widely used.

Its characteristics: high flow rate, average wind pressure

Centrifugal fan

Centrifugal fan, blade air moving in a direction perpendicular to the axis of phase (radial) flow, inlet is along the axis direction, and the gas is perpendicular to the axis direction. In most cases, the use of axial flow fan can achieve cooling effect, however, sometimes you rotate it 90 degree if need air discharge or need larger wind pressure, you must choose a centrifugal fan. Strictly speaking, fans are belong to the centrifugal fan.

Its characteristics: limited flow rate, high wind pressure

Mixed flow fan

Mixed flow fan is also called the diagonal flow fan, the first look, mixed flow fans and axial flow fan is no different, in fact, mixed flow fan inlet is along the axis, but outgassing is along the diagonal direction of the axis and vertical axis. This fan because of blade and casing said cone, so the air pressure is higher, under the same size and other comparable performance, compared with axial flow fan, centrifugal fan noise is lower.

Its characteristics: high flow rate and the relatively high wind pressure

Tubular fan

Tubular wind can produce the wind flow of large area, usually used for large surface cooling equipment. The wind

Fan inlet and vent are perpendicular to the axis (right). Tubular fan is to use a longer barrel shaped fan impeller, the round barrel the calibre of the blades are great, because of big diameter, to guarantee the overall on the basis of air circulation using low speed, thereby, reduce the noise caused by the high-speed operation.

Bearing structure

Introduction to the

A cooling fan of the common bearing are: ball bearing, oil bearing, magnetic levitation bearing.

Ball bearing

Ball Bearing, Ball Bearing) changed the way of Bearing friction, adopts rolling friction, there are some among two hoop steel or steel columns, supplemented by some grease lubrication. The way is more effective in reducing the friction between the bearing surface phenomenon, effectively improve the service life of the fan bearing, and so will the heat radiator is reduced, prolong service life. The downside is that technology is more complex, lead to cost increase, at the same time also bring higher noise.

Oil bearing

Oil-retaining Bearing, Sleeve Bearing) is the use of sliding friction Sleeve Bearing, using oil as a lubricant and drag reduction agent. Is now one of the most common bearing technology on the market, due to low cost, simple manufacturing, many products including well-known brands are still continue to use. Its advantage is the early use of quiet, low noise, low price.

Magnetic suspension bearing

Magnetic suspension Bearing, Magnetic Bearing) motor USES the maglev (Magnetic System, MS) design, is the use of Magnetic effect of the rotor suspended in the air, no mechanical contact between the rotor and stator. Is the principle of magnetic induction line with maglev line, vertical shaft core and the maglev line are parallel, so the weight of the rotor is fixed on the orbit, the use is almost without load axial maglev line direction top bracing, form the whole rotor suspended, in a fixed orbit operation. Compared with traditional ball bearing, oil bearing, magnetic bearing, there is no mechanical contact, the rotor can be run to high speed, small mechanical wear and tear, low energy consumption, low noise, long service life, no lubrication, no oil pollution, etc, especially suitable for high speed, vacuum, super clean, etc

Technical indicators

Air volume

Air flow is refers to the cooling fan out or into the air volume per minute, if calculated by cubic feet, air volume unit is CFM. If according to cubic meters to calculate, is to the CMM. A cooling fan often use air unit is CFM (about 0.028 cubic meters per minute).

Air is the most important indicators of cooling fan cooling capacity. Obviously, the greater the volume of cooling fan the higher cooling capacity. This is because the heat capacity ratio of air is certain, larger volume and per unit time is more air can take more heat. Of course, the same air under the condition of the cooling effect and wind flow way.

Wind pressure

Air pressure and air volume are two relative concepts. In general, under the manufacturer's cost considerations, to design the fan air volume is big, have to sacrifice some wind pressure. If the fan can bring a lot of air flow, but the wind pressure is small, the wind is less than the bottom of the radiator (this is why some of the fan speed is high, volume is very big, but it is the reason why cooling effect is not good), on the contrary, the wind is often means that the air volume is small, there is not enough air and heat sink for heat exchange, also causes the cooling effect is not good.

Fan speed

Fan speed is refers to the number of the fan blade rotation per minute, the unit is the RPM. Fan speed by the motor coil number of turns, working voltage, the number of the fan blade, Angle and height, diameter, and bearing system common decision. Speed and quality of the fan not necessarily linked. The speed of the fan can be internal speed signal measurement, but can be by external measurements.

As the application situation and the change of environmental temperature, sometimes need different fan speed to meet demand. Some vendors specially designed adjustable fan speed of cooling fan, move and break up two automatically. Mainly is to let users can manually using low speed to obtain low noise in the winter, summer with high speed to obtain good heat dissipation effect. Automatic temperature radiator with a temperature sensor, according to the current working temperature automatic control fan speed, high temperature, improve the speed, low temperature, reduce the speed, in order to achieve a dynamic balance, so that the wind noise and cooling effect to keep a best combining site.

Fan noise

In addition to the heat dissipation effect, fan noise is also a widely concerned problem. The size of the fan noise is generated when the fan noise, influenced by various factors, the unit of decibels (dB). When measuring the noise of the fan needs in the sound attenuation of noise is less than 17 db and fan, one meter distance along the direction of the fan rotor on the fan air inlet, measured using A weighted way. The fan noise spectrum characteristics is also very important, so you also need to use spectrometer to record the noise of the fan frequency distribution, generally requires little as far as possible, the noise of the fan and cannot exist different sounds.

Fan noise is related to the friction, air flow. The fan speed is higher, the air volume, the greater the noise caused by the will, the greater the wind ? additionally

application

Widely used in computers, communication products, photoelectric products, consumer electronics, automotive electronics equipment, switches, medical devices, heaters, air conditioners, frequency converter, ATM, automobile air-conditioner, welding machine, induction cooker, audio equipment, environmental equipment, refrigeration equipment, such as traditional or modern instruments and equipment.

 

Address: The 3th Floor,A Building,Yi Quan Industrial Zone,No434,Fu Qian Road,Guan Lan Town,Bao An District,Shen Zhen City,Guang Dong Province.

Telephone: 0755-28010785/29357130

Phone: 13662569855

Consulting QQ: 3117283658

Contact: ms luo

Fax: 0755-28010562

Website: http://www.sanrefengji.com/